1730–Series Checks and Adjustments
5–15
shows the location of R856. Connect a 0 to +10 V, 2 kHz square wave
to the bnc connector of the Parade Display Test Connector, as shown in
the equipment list.
h. CHECK – that 7.6 to 10.4 divisions of deflection have been added by
the square wave.
8. Check 90/100 Hz Triggering
REQUIREMENT – 90 Hz,
±
15% (100 Hz,
±
15%).
a. Connect the function generator output through a dual input coupler and
an in–line 75
W
terminator to the 1730–Series CH–A INPUT.
b. Set the function generator for a 90 Hz (100 Hz PAL) 2 V p–p square
wave.
c.
Install the bnc to alligator clip adapter on the remaining side of the dual
input coupler.
d. Install the 90/100 Hz sub–miniature D–connector on the 1730–Series
REMOTE connector. See Fig. 5-2.
e.
Connect the alligator clip from the center connector (red) to pin 10 of the
sub–miniature D–connector adapter.
f.
Move the jumper for J540 (90/100 Hz Enable) to the 1–2 position. See
Fig. 5-7.
g. Move the jumper for J635 to the negative position (2–3). See Fig. 5-7.
h. Select 2FLD SWEEP.
i.
Set the 1730–Series VAR GAIN for a 1 V p–p square wave, 90 Hz
output (100 Hz PAL).
j.
CHECK – that the display remains stable (although sweep length
varies) while varying the generator from 76 to 104 Hz (85–115 Hz PAL).
k. If 90/100 Hz triggering is not going to be used, move the jumpers on
J540 to the 2–3 position and J635 to the 1–2 position.
l.
Remove the adapter from the 1730–Series rear–panel REMOTE
connector.
9. Check Vertical Gain and X5 Gain Registration
REQUIREMENT – Gains within 1% for both CH–A and CH–B INPUT. X5
gain within 5%. Input signals between 0.8 and 2 V can be adjusted to full–scale
Summary of Contents for 1730 Series
Page 4: ......
Page 12: ...Contents viii...
Page 17: ...Introduction and Specifications...
Page 18: ......
Page 32: ...1730 Series Introduction 1 14...
Page 33: ...Operating Instructions...
Page 34: ......
Page 62: ...1730 Series Operating Instructions 2 28...
Page 64: ...Service Safety Summary S 2 1730 Series B070000 Above...
Page 66: ......
Page 67: ...Installation...
Page 68: ......
Page 82: ...1730 Series Installation 3 14...
Page 83: ...Theory of Operation...
Page 84: ......
Page 115: ...Checks and Adjustments...
Page 116: ......
Page 159: ...Maintenance...
Page 160: ......
Page 180: ...1730 Series Maintenance 6 20 3 Remove the board by slipping it through the front panel opening...
Page 184: ...1730 Series Maintenance 6 24 Figure 6 8 Repackaging a 1730 Series instrument...
Page 185: ...Options...
Page 186: ......
Page 189: ...Replaceable Electrical Parts...
Page 190: ......
Page 222: ...1730 Series Replaceable Electrical Parts 8 32...
Page 223: ...Diagrams Circuit Board Illustrations...
Page 224: ......
Page 246: ......
Page 247: ...Replaceable Mechanical Parts...
Page 248: ......
Page 255: ...1730 Series Waveform Monitor FIG 1 EXPLODED VIEW A1 A3 A2 A3A1 A10 A11...
Page 256: ...1730 Series B070000 Up...
Page 257: ......
Page 258: ......