1730–Series Operating Instructions
2–5
14 INTENSITY
Controls display brightness.
15 ON
Switches between instrument in a powered up state and in standby. Portions of
the power supply circuit board still have mains potential on them. A mechanical
indicator in the center of the switch shows the status of the POWER switch.
WARNING. Power Supply Hazard:
Mains power is still applied to the 1730–Series power supply circuit board,
regardless of POWER switch state. To totally remove shock hazard it is
necessary to unplug the instrument and wait for capacitors to discharge.
16 ON
Toggles between ON and OFF. Line and field number are displayed on the CRT
in 1LINE or 2LINE sweep rates with a colon as a delimiter, for example: F1:19
(field 1, line 19). In LINE SELECT mode, the selected line is displayed in
1LINE sweep rate, the selected line is displayed first in the 2LINE sweep rate,
and a bright–up is provided to mark the selected line in 2FLD sweep rate. The
field from which the line will be displayed can be selected with the FIELD
switch.
15 LINE display is accessed by holding the LINE SELECT ON button until
there is recognition. In 2FLD, the 15 lines are intensified in the display. In 1 or
2LINE sweeps, the 15 lines are overlayed and the CRT readout is active, giving
the field and line of the first displayed line plus a small 15 immediately below
the colon in the readout.
Lines displayed in the LINE SELECT mode have their active video intensified
on the PIX MON OUT signal.
17 UP
Increments the line count (when enabled). Holding the UP push button in
increments faster.
Power
Line Select
Summary of Contents for 1730 Series
Page 4: ......
Page 12: ...Contents viii...
Page 17: ...Introduction and Specifications...
Page 18: ......
Page 32: ...1730 Series Introduction 1 14...
Page 33: ...Operating Instructions...
Page 34: ......
Page 62: ...1730 Series Operating Instructions 2 28...
Page 64: ...Service Safety Summary S 2 1730 Series B070000 Above...
Page 66: ......
Page 67: ...Installation...
Page 68: ......
Page 82: ...1730 Series Installation 3 14...
Page 83: ...Theory of Operation...
Page 84: ......
Page 115: ...Checks and Adjustments...
Page 116: ......
Page 159: ...Maintenance...
Page 160: ......
Page 180: ...1730 Series Maintenance 6 20 3 Remove the board by slipping it through the front panel opening...
Page 184: ...1730 Series Maintenance 6 24 Figure 6 8 Repackaging a 1730 Series instrument...
Page 185: ...Options...
Page 186: ......
Page 189: ...Replaceable Electrical Parts...
Page 190: ......
Page 222: ...1730 Series Replaceable Electrical Parts 8 32...
Page 223: ...Diagrams Circuit Board Illustrations...
Page 224: ......
Page 246: ......
Page 247: ...Replaceable Mechanical Parts...
Page 248: ......
Page 255: ...1730 Series Waveform Monitor FIG 1 EXPLODED VIEW A1 A3 A2 A3A1 A10 A11...
Page 256: ...1730 Series B070000 Up...
Page 257: ......
Page 258: ......