1730–Series Checks and Adjustments
5–25
c.
Select Demod/TG on the spectrum analyzer. Turn on the tracking
generator and set the tracking generator fixed level to 0.00 dBm.
d. Set the spectrum analyzer Span/Div to 1 MHz and the Resolution
Bandwidth to 30 kHz.
e.
Set the spectrum analyzer Vertical Scale to 10 dB.
f.
Set the spectrum analyzer Reference Level to the first major division
down from the top on the analyzer display.
g. Remove one of the cables from the RF Bridge.
h. Set the spectrum analyzer Frequency to 5 MHz and turn the Marker on.
Set the Marker to 6 MHz.
i.
Reconnect the cable to the RF Bridge.
j.
Note – the Reference Level Readout.
k. Adjust the spectrum analyzer External Attenuation Amplitude (on the
2712 Input menu) by the amount noted in part j. of this step. Note: The
Reference Level Readout should now be 0.00 dBm.
l.
Connect the precision high-frequency terminator to the Device Under
Test connector on the RF Bridge.
m. Check – that the frequency response from 0 MHz to 6 MHz is
w
40 dBm.
n. Return the spectrum analyzer frequency marker to 6 MHz if it was
moved.
o. Remove the precision high-frequency terminator from the RF Bridge.
p. Connect the male-to-male bnc adapter to the Device Under Test
connector on the RF Bridge.
q. Connect the Device Under Test connector on the RF Bridge to the
1730–Series CH–A INPUT. Terminate the CH–A loop-through with the
same precision high-frequency terminator used in step o.
r.
Select CH–A INPUT.
s.
Check – that the Reference Level Readout on the spectrum analyzer is
w
40 dBm with the instrument power on and off.
t.
Repeat parts q. through s. for each Input channel (CH–B and EXT REF).
u. Remove all cables and terminators from the 1730–Series.
Summary of Contents for 1730 Series
Page 4: ......
Page 12: ...Contents viii...
Page 17: ...Introduction and Specifications...
Page 18: ......
Page 32: ...1730 Series Introduction 1 14...
Page 33: ...Operating Instructions...
Page 34: ......
Page 62: ...1730 Series Operating Instructions 2 28...
Page 64: ...Service Safety Summary S 2 1730 Series B070000 Above...
Page 66: ......
Page 67: ...Installation...
Page 68: ......
Page 82: ...1730 Series Installation 3 14...
Page 83: ...Theory of Operation...
Page 84: ......
Page 115: ...Checks and Adjustments...
Page 116: ......
Page 159: ...Maintenance...
Page 160: ......
Page 180: ...1730 Series Maintenance 6 20 3 Remove the board by slipping it through the front panel opening...
Page 184: ...1730 Series Maintenance 6 24 Figure 6 8 Repackaging a 1730 Series instrument...
Page 185: ...Options...
Page 186: ......
Page 189: ...Replaceable Electrical Parts...
Page 190: ......
Page 222: ...1730 Series Replaceable Electrical Parts 8 32...
Page 223: ...Diagrams Circuit Board Illustrations...
Page 224: ......
Page 246: ......
Page 247: ...Replaceable Mechanical Parts...
Page 248: ......
Page 255: ...1730 Series Waveform Monitor FIG 1 EXPLODED VIEW A1 A3 A2 A3A1 A10 A11...
Page 256: ...1730 Series B070000 Up...
Page 257: ......
Page 258: ......