1730–Series Checks and Adjustments
5–3
For example: TEKTRONIX DM504A in a TM500 Series Power Module.
6. Frequency Counter
Range, 100 kHz to 5 MHz; accuracy,
±
0.001%.
For example: TEKTRONIX DC503A in a TM500 Series Power Module.
7. Video Amplitude Calibrator
Signal, adjustable square wave 0.0 to 999.9 mV p-p with a resolution of 0.1
mV and an accuracy of 0.05%; frequency approximately 270 Hz.
For example: TEKTRONIX 067–0916–00 in a TM500 Series Power
Module.
8. Power Module
for powering and housing TEKTRONIX DM501A, DC503A, FG503,
067–0916–00, and 015–0408–00.
For example: A TEKTRONIX TM506 Power Module.
9. Variable Autotransformer
For example: General Radio Metered Auto Transformer W10MT3W. If 220
volt operation must be checked, a conversion transformer or appropriate 220
volt autotransformer is needed.
10. Spectrum Analyzer with Tracking Generator
Bandwidth
10 MHz and sensitivity to 50 dB.
For example:
TEKTRONIX 2712 Opt 04
11. Peak to Peak Detector Amplifier and Detector Head
Facilitates differential frequency–response measurements. Provides a
high–impedance load and bias for the Peak To Peak Detector Head.
For example: TEKTRONIX 015–0408–00 Peak To Peak Detector Amplifi-
er, includes one 015–0413–00 Peak To Peak Detector Head.
Auxiliary Equipment
Summary of Contents for 1730 Series
Page 4: ......
Page 12: ...Contents viii...
Page 17: ...Introduction and Specifications...
Page 18: ......
Page 32: ...1730 Series Introduction 1 14...
Page 33: ...Operating Instructions...
Page 34: ......
Page 62: ...1730 Series Operating Instructions 2 28...
Page 64: ...Service Safety Summary S 2 1730 Series B070000 Above...
Page 66: ......
Page 67: ...Installation...
Page 68: ......
Page 82: ...1730 Series Installation 3 14...
Page 83: ...Theory of Operation...
Page 84: ......
Page 115: ...Checks and Adjustments...
Page 116: ......
Page 159: ...Maintenance...
Page 160: ......
Page 180: ...1730 Series Maintenance 6 20 3 Remove the board by slipping it through the front panel opening...
Page 184: ...1730 Series Maintenance 6 24 Figure 6 8 Repackaging a 1730 Series instrument...
Page 185: ...Options...
Page 186: ......
Page 189: ...Replaceable Electrical Parts...
Page 190: ......
Page 222: ...1730 Series Replaceable Electrical Parts 8 32...
Page 223: ...Diagrams Circuit Board Illustrations...
Page 224: ......
Page 246: ......
Page 247: ...Replaceable Mechanical Parts...
Page 248: ......
Page 255: ...1730 Series Waveform Monitor FIG 1 EXPLODED VIEW A1 A3 A2 A3A1 A10 A11...
Page 256: ...1730 Series B070000 Up...
Page 257: ......
Page 258: ......