1730–Series Maintenance
6–12
c.
Remove the clip lead from across C47.
5. Error Amplifier Check
a. Connect the negative output from the variable DC power supply to TP1.
Connect the positive output to W1 (+5 V).
b. Connect the negative output of another variable DC power supply to
TP1. Connect the positive output to W4 (+15 V). Set the variable
power supply to 20 VDC.
c.
Connect the digital multimeter between TP1 and the cathode of CR15.
d. Set the variable DC power supply connected to W1 (+5 V) to 4.8 V. The
cathode of CR15 should be approximately 20 V.
e.
Set the variable DC power supply connected to W1 (+5 V) to 5.2 V. The
cathode of CR15 should be approximately 2 V.
f.
If this check did not reveal the cause for the +5 V supply not regulating,
refer to the Output Check and the Control Circuit Check.
1. Preliminary Checks
a. Table 6–5 lists the High Volts Supply fault symptoms and procedures.
Table 6–5: High Volts Supply Fault Symptoms
Symptom
Procedure
Unable to focus CRT using the
front-panel control
Focus Amplifier Check
Unable to adjust CRT intensity using
the front-panel control
Z-Axis Amplifier Check
Grid Drive Check
No CRT display
High Voltage Oscillator Check
CRT Voltage Check
b. Load the Low Volts Supply with the instrument, or with the 20
W
resistor
as detailed at the beginning of the Troubleshooting Procedure.
2. Focus Amplifier Check
a. Unsolder and lift one end of R24.
b. Power up the power supply.
High Volts Supply
Summary of Contents for 1730 Series
Page 4: ......
Page 12: ...Contents viii...
Page 17: ...Introduction and Specifications...
Page 18: ......
Page 32: ...1730 Series Introduction 1 14...
Page 33: ...Operating Instructions...
Page 34: ......
Page 62: ...1730 Series Operating Instructions 2 28...
Page 64: ...Service Safety Summary S 2 1730 Series B070000 Above...
Page 66: ......
Page 67: ...Installation...
Page 68: ......
Page 82: ...1730 Series Installation 3 14...
Page 83: ...Theory of Operation...
Page 84: ......
Page 115: ...Checks and Adjustments...
Page 116: ......
Page 159: ...Maintenance...
Page 160: ......
Page 180: ...1730 Series Maintenance 6 20 3 Remove the board by slipping it through the front panel opening...
Page 184: ...1730 Series Maintenance 6 24 Figure 6 8 Repackaging a 1730 Series instrument...
Page 185: ...Options...
Page 186: ......
Page 189: ...Replaceable Electrical Parts...
Page 190: ......
Page 222: ...1730 Series Replaceable Electrical Parts 8 32...
Page 223: ...Diagrams Circuit Board Illustrations...
Page 224: ......
Page 246: ......
Page 247: ...Replaceable Mechanical Parts...
Page 248: ......
Page 255: ...1730 Series Waveform Monitor FIG 1 EXPLODED VIEW A1 A3 A2 A3A1 A10 A11...
Page 256: ...1730 Series B070000 Up...
Page 257: ......
Page 258: ......