CH–A–CH–B
Switch that toggles between Channel A and Channel B input. When held, the
1730–Series goes into an AB (BOTH) alternate mode, with the A input on the
left and the B input on the right in 2 Line or 2 Field (lines are overlayed in 1
Line sweep). When in the AB switching mode the REF is forced to EXT, the
FILTER is forced to LPASS, if it was in the LPASS–FLAT switching mode; if
not the FILTER remains in the previous position, and the DC REST goes to
SLOW. All three functions go back to their previous setting when the input is
switched out of AB. The DC Restorer can be changed after entering the AB
mode. When leaving (BOTH), the input always returns to CH–A.
4
GAIN (control)
Enabled when the GAIN switch is in VAR. Adjusts amplifier input gain rate to
make any input waveform signal, between 0.8 and 2.0 V peak–to–peak a
full–scale display. Control has no detent.
5
VERTICAL
Toggles between VAR, X5, and off. A BOTH mode consisting of VAR and X5
is accessed by holding the push button until both LED indicators are lit.
6
DC REST
Toggles the DC Restorer on and off. When turned on the restorer comes up as
previously selected, in either the SLOW or FAST position. Pushing and holding
the switch in toggles the restorer between FAST and SLOW. Once the restorer
speed has been selected, pushing the DC REST button turns the DC Restorer on,
at the selected speed, or off.
7
POSITION
Variable control that positions the waveform display vertically.
8
SWEEP
Toggles between 2LINE and 2FLD Sweep. 1LINE Sweep is accessed by
holding the SWEEP push button in until recognition occurs. The MAG is
automatically turned off if SWEEP is changed. Sweep rates are as follows:
2LINE unmagnified = 10
m
s/div
1LINE unmagnified = 5
m
s/div
Horizontal
Summary of Contents for 1730 Series
Page 4: ......
Page 12: ...Contents viii...
Page 17: ...Introduction and Specifications...
Page 18: ......
Page 32: ...1730 Series Introduction 1 14...
Page 33: ...Operating Instructions...
Page 34: ......
Page 62: ...1730 Series Operating Instructions 2 28...
Page 64: ...Service Safety Summary S 2 1730 Series B070000 Above...
Page 66: ......
Page 67: ...Installation...
Page 68: ......
Page 82: ...1730 Series Installation 3 14...
Page 83: ...Theory of Operation...
Page 84: ......
Page 115: ...Checks and Adjustments...
Page 116: ......
Page 159: ...Maintenance...
Page 160: ......
Page 180: ...1730 Series Maintenance 6 20 3 Remove the board by slipping it through the front panel opening...
Page 184: ...1730 Series Maintenance 6 24 Figure 6 8 Repackaging a 1730 Series instrument...
Page 185: ...Options...
Page 186: ......
Page 189: ...Replaceable Electrical Parts...
Page 190: ......
Page 222: ...1730 Series Replaceable Electrical Parts 8 32...
Page 223: ...Diagrams Circuit Board Illustrations...
Page 224: ......
Page 246: ......
Page 247: ...Replaceable Mechanical Parts...
Page 248: ......
Page 255: ...1730 Series Waveform Monitor FIG 1 EXPLODED VIEW A1 A3 A2 A3A1 A10 A11...
Page 256: ...1730 Series B070000 Up...
Page 257: ......
Page 258: ......