4-19
Group 02 IM Motor Parameters
Code
Parameter Name
Setting Range
Default Unit
Control mode
Attribute
V/F
SLV
PM
SLV
02-00 No-Load Current of Motor1
0.01~600.00
-
A
O
X
X
02-01 Rated Current of Motor1
V/F mode: 10%~200% of inverter
rated current.
SLV mode:
25%~200% of inverter
rated current.
-
A
O
O
X
02-03
Rated Rotation Speed of
Motor1
0~60000
-
rpm
O
O
X
02-04 Rated Voltage of Motor1
200V: 50.0~240.0
230.0
V
O
O
X
*8
400V: 100.0~480.0
400.0
02-05 Rated Power of Motor1
0.01~600.00
-
kW
O
O
X
02-06 Rated Frequency of Motor1
4.8~599.0
50.0/60.0 Hz
O
O
X
*8
02-07
Number of Motor Poles of
Motor 1
2~16(Even)
4
-
O
O
X
02-09 Excitation Current of Motor 1
15%~70% of motor rated current
-
%
X
O
X
02-10 Core Saturation Coefficient 1
1~100
-
%
X
O
X
02-11
Core Saturation
Coefficient 2 of Motor 1
1~100
-
%
X
O
X
02-12
Core Saturation
Coefficient 3 of Motor 1
80~300
-
%
X
O
X
02
-
13 Core loss of Motor 1
0.0~15.0
-
%
O
X
X
02-15
Line-to-line Resistance
Motor 1
1~60.000
Ω
O
O
X
02-16 Rotor Resistance of Motor 1
1~60.000
Ω
O
O
X
02-17
Leakage Inductance of
Motor 1
0.01~200.00
-
mH
O
O
X
02-19 No-Load Voltage of Motor 1
200V
:
50~240
-
V
X
O
X
400V
:
100~480
-
02-20 No-Load Current of Motor 2
0.01~600.00
-
A
O
X
X
02-21 Rated Current of Motor 2
10%~200% of inverter rated current
-
A
O
X
X
02-22
Rated Rotation Speed of
Motor 2
0~60000
-
Rpm
O
X
X
*8
02-23 Rated Voltage of Motor 2
200V
:
50.0~240.0
230.0
V
O
X
X
400V
:
100.0~480.0
400.0
02-24 Rated Power of Motor 2
0.01~600.00
-
kW
O
X
X
02-25 Rated Frequency of Motor 2
4.8~599.0
50.0/60.0 Hz
O
X
X
*8
02-26
Number of Motor Poles of
Motor 2
2~16 (Even)
4
-
O
X
X
02-32
Line-to-line Resistance
Motor 2
0.001~60.000
-
Ω
O
X
X
02-33
Proportion of Motor Leakage
Inductance
0.1~15.0
3.4
%
X
O
X
02-34 Slip Frequency of Motor
0.10~20.00
1.00
Hz
X
O
X