4-141
06 Automatic Program Operation
06- 00
Auto Run Mode Select
Range
【
0
】
:
Disabled
【
1
】
:
Execute a single cycle operation. Restart speed is based on the previous stopped speed.
【
2
】
:
Execute continuous cycle operation. Restart speed is based on the previous cycle stop speed.
【
3
】
:
After completion of a single cycle, the on-going operation speed is based on the speed of the
last stage. Restart speed is based on the previous stopped speed.
【
4
】
:
Execute a single cycle operation. Restart speed is based on the Speed-Stage 0.
【
5
】
:
Execute continuous cycle operation. Restart speed is based on the Speed-Stage 0.
【
6
】
:
After completion of a single cycle, the on-going operation speed is based on the speed of the
last stage. Restart speed is based on the Speed-Stage 0
Range
【
0.00~599.00
】
Hz
Frequency setting of speed-stage 0 is based on parameter 05-01
06-01
Frequency setting of speed-stage 1
06-02
Frequency setting of speed-stage 2
06-03
Frequency setting of speed-stage 3
06-04
Frequency setting of speed-stage 4
06-05
Frequency setting of speed-stage 5
06-06
Frequency setting of speed-stage 6
06-07
Frequency setting of speed-stage 7
06-08
Frequency setting of speed-stage 8
06-09
Frequency setting of speed-stage 9
06-10
Frequency setting of speed-stage 10
06-11
Frequency setting of speed-stage 11
06-12
Frequency setting of speed-stage 12
06-13
Frequency setting of speed-stage 13
06-14
Frequency setting of speed-stage 14
06-15
Frequency setting of speed-stage 15
Range
【
0.0~6000.0
】
Sec
06-16
Operation time setting of speed-stage 0
06-17
Operation time setting of speed-stage 1
06-18
Operation time setting of speed-stage 2
06-19
Operation time setting of speed-stage 3
06-20
Operation time setting of speed-stage 4
06-21
Operation time setting of speed-stage 5
06-22
Operation time setting of speed-stage 6
06-23
Operation time setting of speed-stage 7
06-24
Operation time setting of speed-stage 8