![TECO-Westinghouse E510-201-H-U Instruction Manual Download Page 48](http://html.mh-extra.com/html/teco-westinghouse/e510-201-h-u/e510-201-h-u_instruction-manual_1072541048.webp)
3-30
200V Class
:
Three phase
Model
:
E510-
□□□-H3-U
202
205
208
210
215
220
Horse power (HP)
2
5
7.5
10
15
20
Suitable motor capacity (KW)
1.5
4
5.5
7.5
11
15
Rated output current (A)
7.5
17.5
26
35
48
64
Rated capacity (KVA)
2.9
6.7
9.9
13.3
20.6
27.4
Input voltage range(V)
Three phase
:
200~240V,50/60HZ
Allowable voltage fluctuation
-15%~+10%
Output voltage range(V)
Three phase
:
0~240V
Input current (A)*
11
20.5
33
42
57
70
Inverter net weight (KG)
1.6
2.5
6.5
6.5
10.1
10.4
Allowable momentary power loss
time(s)
2.0
2.0
2.0
2.0
2.0
2.0
Enclosure
IP20/NEMA1
Model
:
E510-
□□□-H3-U
225
230
240
Horse power (HP)
25
30
40
HD/ND Suitable motor capacity
(kW)
18.5/22
22/30
30/37
HD/ND Rated output current (A)
73/80
85/110
115/138
HD/ND Rated capacity (KVA)
27.8/30.1
32.4/41.9
43.8/52.6
Input voltage range(V)
Three phase
:
200~240V,50/60HZ
Allowable voltage fluctuation
-15%~+10%
Output voltage range(V)
Three phase
:
0~240V
Input current (A)*
79.4/85.9
92.4/119.6
125/150
Inverter net weight (KG)
10
30
30
Allowable momentary power loss
time(s)
2.0
2.0
2.0
Enclosure
IP20/NEMA1