Produzido por Tecnomotor Eletrônica do Brasil S/A - REPRODUÇÃO PROIBIDA - Eventuais erros ou defeitos favor comunicar [email protected]
237
TM 514 – COMMON RAIL TEST
Error
Code
179
CH1 optical module disconnected
Probable Cause
Solution
- Bad contact on sensor(s) connections.
- Contact the manufacturer.
Error
Code
180
CH2 optical module disconnected
Probable Cause
Solution
- Bad contact on sensor(s) connections.
- Contact the manufacturer.
Error
Code
192
Direct injection tightness test failed
Probable Cause
Solution
- Injector in trouble.
- Occurrence of error 195/196.
- Contact the manufacturer.
Error
Code
193
CH1 measurement timeout
Probable Cause
Solution
- Jet breaker adapter disconnected.
- Leak in drain valves.
- 3 way valves disconnected.
- 3 way valves with leaks.
- Check jet breaker connections.
- Check actuation of 3 way valves.
- Check for leaks in 3-way valves.
- Check valve fuse.
Error
Code
194
CH2 measurement timeout
Probable Cause
Solution
- Jet breaker adapter disconnected.
- Leak in drain valves.
- 3 way valves disconnected.
- 3 way valves with leaks.
- Check jet breaker connections.
- Check actuation of 3 way valves.
- Check for leaks in 3-way valves.
- Check valve fuse.
Error
Code
195
Impossible to empty the meter CH1
Probable Cause
Solution
- Accumulation of impurities in the hydraulic
system.
- Bad contact at the drain valve connections.
- Damaged power board.
- Blown valve fuse.
- Check valve fuse.
- Apply 'auto clean' functionality to production
test actuators.
Error
Code
196
Impossible to empty the meter CH2
Probable Cause
Solution
- Accumulation of impurities in the hydraulic
system.
- Bad contact at the drain valve connections.
- Damaged power board.
- Blown valve fuse.
- Check valve fuse.
- Apply 'auto clean' functionality to production
test actuators.