83-530-000 Rev. G
61
The power supply can accept values higher 5% than the table values, however it is not recommended to
program the power supply over the rated values.
Table 7-5: OVP programming range
Table 7-6: UVL programming range
Model
Rated Output Voltage (V)
Minimum
(V)
Maximum
(V)
Model
Rated Output Voltage (V)
Minimum
(V)
Maximum
(V)
7.5-1000
0.75
8.25
7.5-1000
0
7.125
10-1000
1
11
10-1000
0
9.5
12.5-800
1.25
13.75
12.5-800
0
11.875
20-500
2
22
20-500
0
19
25-400
2.5
27.5
25-400
0
23.75
30-333
3
33
30-333
0
28.5
40-250
4
44
40-250
0
38
50-200
5
55
50-200
0
47.5
60-167
6
66
60-167
0
57
80-125
8
88
80-125
0
76
100-100
10
110
100-100
0
95
125-80
12.5
137.5
125-80
0
118.75
150-66
15
165
150-66
0
142.5
200-50
20
220
200-50
0
190
250-40
25
275
250-40
0
237.5
300-33
30
330
300-33
0
285
400-25
40
440
400-25
0
380
500-20
50
550
500-20
0
475
600-17
60
660
600-17
0
570
7.9.6
Status Control Commands
Refer to Section 7-10 for definition of the registers.
#
Command
Description
1
STT?
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas:
MV<actual (measured) voltage>
PC<programmed (set) current>
PV<programmed (set) voltage>
SR<status register, 2-digit hex>
MC<actual (measured) current>
FR<fault register, 2-digit hex>
Example response: MV(45.201),PV(45), MC(4.3257), PC(10), SR(30), FR(00)
2
FLT?
Reads Fault Conditional Register. Returns 2-digit hex.
3
FENA
Set Fault Enable Register using 2-digit hex.
4
FENA?
Reads Fault Enable Register. Returns 2-digit hex.
5
FEVE?
Reads Fault Event Register. Returns 2-digit hex. Clears bits of Fault Event Register.
6
STAT?
Reads Status Conditional Register. Returns 2-digit hex.
7
SENA
Sets Status Enable Register using 2-digit hex.
8
SENA?
Reads Status Enable Register. Returns 2-digit hex.
9
SEVE?
Reads Status Event register. Returns 2-digit hex. Clears bits of Status Event register.