TASCAM SS-CDR250N / SS-R250N
37
4 – Playback
Using the ducking function
When the ducking function is active, signals input to this unit
and playing back from the recorder are mixed and output.
Select
DUCKING
on the
PLAY 2
page to open the
DUCKING
screen.
(See “Menu operation procedures” on page 22.)
NOTE
i
When the
DUCKING
screen is open, use the
m
[A-B] and
,
[INPUT] buttons to move the cursor between setting
items.
i
When the ducking function is active, ducking tally signals are
output from the PARALLEL connector.
Input source information display
This shows the selected input source. (See “Selecting the input
source” on page 56.)
Setting the ducking function operation mode
Select
MODE
, and set the ducking function operation mode.
Option
Meaning
OFF
(default)
The ducking function is disabled.
ATT. INPUT
When the recorder playback signal level
exceeds the
THRESHOLD
level setting, the
analog input signal is reduced by the
AT-
TENUATION
level setting.
ATT. PLAYBACK
When the input signal level exceeds the
THRESHOLD
level setting, the recorder play-
back signal is reduced by the
ATTENUATION
level setting.
Setting the ducking threshold level
Select
THRESHOLD
, and set the ducking operation threshold level.
Options:
-30dBFS
,
-24dBFS
,
-18dBFS
,
-12dBFS
,
-6dBFS
(default)
Setting the ducking attenuation (reduction) level
Select
ATTENUATION
, and set the ducking attenuation (reduction)
level.
Options:
-INFINITY
,
-24dB
,
-18dB
,
-12dB
,
-9dB
,
-6dB
,
-3dB
(default)
Setting the time until ducking stops after the signal goes
below the threshold level
Select
RELEASE TIME
, and set the time until ducking stops after
the signal goes below the threshold level.
Options:
0.1sec
(default),
0.5sec
,
1.0sec
,
1.5sec
,
2.0sec
,
2.5sec
,
3.0sec
,
3.5sec
,
4.0sec
,
4.5sec
,
5.0sec
Using the EOM function
Turn the EOM function on to output an EOM tally signal from the
PARALLEL connector when the remaining time of the track or
playback area becomes less than a set time.
Setting the EOM tally output trigger
1.
Select
EOM TRACK
or
EOM MEDIA
on the
PLAY 2
page. (See
“Menu operation procedures” on page 22.)
EOM TRACK
: Trigger with track remaining time
EOM MEDIA
: Trigger with playback area remaining time
2.
Set the amount of remaining time for the track or playback
area that will trigger EOM tally signal output.
Options:
OFF
(default),
0sec
–
99sec
(in
1sec
intervals)
NOTE
If
EOM TRACK
is set to
0s
a pulse of about 100ms will be out-
put when the track finishes.
3.
Confirm the setting and return to the Menu Screen.
Using this function
1.
Connect the device to receive the EOM tally signal to the
PARALLEL connector.
2.
Turn this unit and the receiving device on.
3.
Start playback on this unit.
When the remaining time of the track or playback area becomes
less than the set time, an EOM tally signal will be output from
the PARALLEL connector.
When when both track and playback area triggers are set, an