96
WEB Interface
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
ID: um_tsmux
POH SD
Path Overhead, degraded Signal Defect
POH EED
Path Overhead, Excessive Error Defect
The
Taffic Queues
field allows mapping of network traffic queues to VLAN priorities. For
information on VLAN priority usage refer to
.
To aid troubleshooting while changing configuration the
Module Alarm
and
Module Error Coun-
ters
fields of the status page are replicated here.
At the bottom of the page are three buttons:
Apply
Writes changes to the SFP configuration file. Also initiates writing the configuration file to
the module if the
Write to module
box has been ticked.
Refresh
Cancels changes that have been entered.
Reset Factory Defaults
Only active if the
Write to module
box has not been ticked. Clicking this button returns
the module to factory default settings but will not affect the settings of the configuration
page. The status of the SFP module is at all times displayed in the
SFP Status
sub-page.
The
E3/T3 Config
page.
The E3T3 module provides an electrical interface for high speed data communications in E3 or
T3 networks. This page provides access to change the configuration settings of the module. As
shown in figure
the page contains four fields to set operational parameters. Editing
the configuration settings will alter the SFP configuration file stored in the CP525, only.
E3/T3 present
Indicates if the module has been detected by the CP525.
Write to module
This box must be checked to allow the configuration file be written to the SFP module.
If the box is not checked the configuration file may still be edited without affecting the
module. If the box is checked the configuration file is written to the module every time
the
Apply
button is clicked.
Interface type
Click the appropriate button for the network used.
Module protocol
Allows selecting the desired data link protocol for the network; HDLC (High Level Data
Link Control), GFP (Generic Frame Protocol) or cHDLC (Cisco extension to HDLC).
Line type
Line protocol selection. Choices vary according to the interface type and data link protocol
selected.
Summary of Contents for CP525 cMux
Page 2: ......
Page 10: ......
Page 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 66: ...66 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 238: ...238 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 248: ...248 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 276: ...276 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...