184
WEB Interface
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
ID: um_tsmux
In Rate
The input bitrate of this PID.
Out PID
The PID value to use and signal inn the output. A remapping configured for the component
is indicated with an "R" for a local-to-service remapping, and an "R" over a globe for global
remapping.
Mode
The rule to apply for this component. The options are:
Default
Use the default mode for the service as specified in
Default Mode
Include
Transmit and signal this component if signalled in input.
Exclude
Stop elementary stream and remove signalling of this component.
Pri Queue
The priority queue to use for this component. The presence of this field depends on a
licence key. It can be set to one of 15 queues that can be named by the user. It is also
possible to select the
Port Default
option, where the queue defined for the given input
will be used. Configuration of port default priority is shown in
. For
more on prioritisation of data, see
and
for setup of queue
prioritisation.
Figure
points at important screen elements on the
Components
tab.
There are three main operations in the component dialogue:
Add
,
Remove
and
Edit
. These are
described in the following.
The Add button
This is used to add a new service component that is signalled in a service on any input port(s)
or to add a custom component. In this way you may add configuration for a service component
that is not present at the moment, or you may add signalling of a service component from
a different service to include this PID in the output. Note that this may not work in target
decoders if the component carries the PCR.
Clicking the
Add
button and selecting
From input
brings up a dialogue
where the
port for the PID, the service containing the PID, and then the PID itself (or a component tag) is
selected. A new output PID may be assigned to the component as well, selecting either between
global or local remap as described before.
Input Port
The input port where the component is or will be signalled. A selection box shows available
input ports.
Input service ID
The service in which the signalling should be regenerated. Type a service ID or selection
one from the list of services currently present on the selected input port.
Summary of Contents for CP525 cMux
Page 2: ......
Page 10: ......
Page 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...