Playout arbitration mode
This parameter selects arbitration characteristics for playout of EIT schedule sections. This
mode only has effect when a specific table ID (e.g. 0x50) is split into two or more groups
with different repetition rates.
The pull-down list provides a choice of values. The value chosen determines the number
of sections that will be played out in sequence at a time for a given table ID. The meaning
of the different values are:
Section
Sections from different groups can be played out in any order. Segments from different
groups may be interleaved.
Segment
When playout of one segment (8 sections) start, it will not be interrupted by other
segments until playout of the current segment is complete.
Group
Playout of one group (several segments) must be completed before any other group
will be allowed to transmit segments. This mode will lead to quite large variations in
measured repetition rate, but the playout sequence will be orderly.
The default value for EITs playout arbitration mode is "Segment".
Use constant section interval
This parameter is only effective when the arbitration mode is set to "Section". The parameter
specifies how the sections of a particular table (indicated by a table ID) will be played out.
If set to true, the player will calculate an
average
section repetition interval for all groups
and play out exactly one section at the end of each interval. If set to “false”, each group
will be played out independent of each other. Sections within each group will have a
distance that corresponds to the repetition interval for sections within that group only. If
the arbitration mode is set to “Segment” or “Group” a constant section interval will always
be used.
The "Use sliding window", "Use expired events" and "Expired Actual Interval/Other In-
terval" options are not supported yet, but may become available in the future.
Groups
The EIT schedule can be divided into up to 4 different groups with different playout
intervals, each group consisting of an integer number of days (1 quarter of a sub-table).
This is typically used to configure faster playout of the EIT data for the first days, and
slower repetitions for EIT data for later days.
When setting a group to 0 days the group is not used.
8.7.2.8.3 EIT/ETT Sch
This page is not available when the output is in DVB mode.
Summary of Contents for CP525 cMux
Page 2: ......
Page 10: ......
Page 12: ...12 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 18: ...18 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 24: ...24 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 66: ...66 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 238: ...238 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 248: ...248 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...
Page 276: ...276 CP525 cMux User s Manual Rev 5 20 12 3944 ID um_tsmux ...