background image

USER’S MANUAL 

 

1. 

SUMMARIZE

 

This meter is a handheld automatic range digital multiemter which 

driven by battery. It can be used to measure such parameters as DCV,   

ACV,  ACA, Resistance, Continuity Buzzer, Diode, Frequency, 

Temperature, etc. 

2.

 GENERAL

 

Displaying

Max. displaying:4000

   

Sampling rate: approx. 3 times/second. 

Polarity indication

Automatic negative polarity indication 

Over range indication

” OL” shown on the LCD 

Low battery indication:

           

 appears 

Operation environment

0

℃~

40

℃,

R.H.< 75%. 

Storage environment

-10

℃~

50

℃,

R.H.<80%. 

Power supply

Size AAA

1.5V

×

Size

193

×

73

×

37mm 

Weight

about 220g. 

Accessories

user’s manual

battery

testleads

temperature probes

 

3.

 TECHNICAL CHARACTERISTIC

 

Accuracy:

±

(a%×rdg

d)    Temperature:(23

±

5)

℃,

R.H.<75% 

3-1.ACV

V

~)

 

RANGE ACCURACY

 

4V/40V/400V

 

±(0.8%+10d)

 

600V 

±(1.0%+10d)

 

Input impedance

10M

Ω

 

Frequency response

SIN wave and triangular wave is 40Hz

1kHz, 

other wave is 40Hz

200Hz 

3-2.DCV

       

   

RANGE ACCURACY  RESOLUTION 

400mV 

±

(0.5%+7d) 

0.1mV 

4V 1mV 

40V 10mV 

400V 100mV 

600V 

±

(1.0%+6d) 

1V 

Input

 impedance

10M

Ω

 

3-3.RESISTANCE

auto range

 

RANGE ACCURACY  RESOLUTION 

400

Ω

 

±

(1.0%+5d) 

0.1

Ω

 

4k

Ω

 

1

Ω

 

40k

Ω

 

10

Ω

 

400k

Ω

 

100

Ω

 

40M

Ω

 

±

(1.2%+10d) 

10kΩ 

3-4.ACA  A

(

auto range

 

Frequency response

50

60Hz 

3-5.FREQUENCY  Hz

(

auto range

 

RANGE ACCURACY  RESOLUTION 

1Hz  

 

 

±

(0.3%+3d) 

0.01Hz 

10Hz 0.1Hz 

100Hz 1Hz 

1kHz 10Hz 

10kHz 100Hz 

100kHz 1kHz 

1MHz 10kHz 

10MHz 100kHz 

Shows zero when the signal is less than 3Hz

sensitivity

1V RMS 

3-6.CAPACITANCE  

(

auto range) 

RANGE ACCURACY  RESOLUTION 

4nF 

±

(5.0%+40d) 

1pF 

40nF  

 

±

(5.0%+10d) 

10pF 

400nF 100pF 

4uF 1nF 

40uF 10nF 

1000uF 1uF 

3-7.TEMPERATURE  

℃/℉

 

RANGE ACCURACY

 

-20

℃~

400

 

±

(3.0%+2d) 

-4

℉~

752

 

4.

 FRONT PANEL DESCRIPTION

 

4-1.

Data Hold Key

HOLD/BL

 

When press the key, the “HOLD” symbol and the last reading of the 

meter will be shown on the LCD, the symbol will disappear until 

press the key again or turn the function switch, and the readings 

comes back. Press “HOLD/BL

key to turn on the meter, the “APO” 

symbol disappear, the auto power off function canceled. If turn on the 

meter by switch as usual, the auto power off function is on, the meter 

will turn off in 15 minutes if without any operation. This key got a 

backlight function, press this key for 3 seconds, the backlight on; if 

press this key again for more than 3 seconds, the backlight off. 

4-2.Select Key

SELECT

 

Turn switch to     or     range, press the key can choose the 

function you wish. 

Turn to range 

℃/℉

, and press the key can transform the unit 

between 

℃/℉.

 

4-3.Range Select Key

RANGE

 

ACV, DCV, ACA, RESISTANCE, etc. can be changed to auto range or 

manual range by pressing the key. When it is under auto range, press 

the key, then the “AUTO” symbol disappear. Then press the key for 

RANGE ACCURACY  RESOLUTION 

4A 

±

(4.0%+10d) 

 

0.001A 

40A 0.01A 

400A 0.1A 

600A 1A 

Reviews: