12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 213
Output Modules
AMI 20-Output Module
Making Signal Connections
The output signals are available at the 50-pin connectors located on the rear panel
of the shelf. Outputs one through twenty are used by this module. Refer to
Making
Output Signal Connections
, on page 56, for more information.
Operational Check
With power applied to the main shelf, install the AMI 20-Output modules in the
appropriate slots and verify that each POWER indicator is lit. This indicates that the
modules are receiving power and the power supplies are working.
Check the INPUT FAULT A and INPUT FAULT B indicators. With two functional
Frame Generators installed, both indicators should be off. If one or no Frame
Generator is installed, the appropriate indicator should be on, indicating that the
signals from that Frame Generator are missing.
If at least one functional Frame Generator is installed, the OUTPUT FAULT indicator
should go out within eight seconds after the AMI 20-Output module is installed. If it
does not, an output may be bad or has an excessive load connected to it (for
example, it may be shorted). The indicator will remain on if there is no reference
connected, because there can be no outputs.
Note:
The module indicators may take a few seconds after
installation to reach proper operating status.