TL1 Reference
Set Commands
382
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Set Phase Zero
The Set Phase Zero command sets the input phase to zero for the specified input,
or for all inputs if the aid is null or All. If no clksrc is specified, both clocks are set to
zero, otherwise the specified clock is set to zero.
When the TSG-3800 successfully receives the command and if the aid is valid, it
returns the COMPLD message. If the TSG-3800 does not successfully receive the
command, it returns the DENY message.
Set AutoReturn
The Set AR Parameter command turns the input reference AutoReturn (revertive)
parameter on or off.
If the TSG-3800 successfully receives the command, it returns the COMPLD
message. If the TSG-3800 does not successfully receive the command, it returns
the DENY message.
Command Syntax
SET-PHASE-ZERO:[tid]:[aid]:ctag[::clksrc];
Valid aid
none or INPx[-y]
clksrc = CLKA or CLKB
Minimum User Level
Example Command
SET-PHASE-ZERO:TSG3800:INP4-2:CLKA;
Example Response
TSG3800 02-05-16 16:21:05
M 15 COMPLD
;
Command Syntax
SET-PRMTR-AR:tid::ctag::mode;
Valid aid
none required
mode = On or Off
Minimum User Level
2
Example Command
SET-PRMTR-AR:TSG3800::ctag::ON;
Example Response
TSG3800 02-09-11 09:45:00
M 623 COMPLD
;