System Administrator’s Reference
Setting Communication Parameters
318
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
COMM [A|B] EOL
then press
Enter
A typical response from the TSG is:
TSG->COMM A EOL
COMM A
Mode: ASCII TimeOut: 300
Baud: 9600 Hand: Off Echo: On EOL: CRLF
Operator: COMM A
TSG->
To change the current EOL setting, type:
COMM [A|B] EOL [CR|LF|CRLF]
then press
Enter
Using the PASSTHRU Mode
The PASSTHRU mode is used to pass commands through the TSG-3800 from one
COMM port to another instrument connected to a serial port. The port to be
connected to another instrument is placed in PASSTHRU mode by issuing the
COMM MODE command. A connection to that port may be established by issuing
the ENABLE PASSTHRU command. To end this mode of operation, disable
PASSTHRU by sending a
Break
character. Procomm uses the
ALT-B
keys to send
a break.
Setting Ethernet Parameters
The TL1 operating mode allows two sessions on port 4000. Passthru mode allows
one session on port 4200. A telnet session allows four sessions on port 23. Before
starting these sessions, you must have an Ethernet connection and set up the
Internet Protocol settings (IP address, gateway address, and the subnet mask)
through an EIA-232 port. You must set up the network parameters before network
communications are possible. The IP address is the unique address for the device.
The gateway address is the default gateway address. This allows the unit to access
other networks. The subnet mask is the mask for the network class. To write the IP
parameters to non-volatile memory, you must restart the CPU by issuing the
RESTART
command.
To change the IP address, type:
IP ADDR {address}
then press
Enter
A typical value is 255.255.255.0
To change the gateway address, type:
IP GATE {address}
then press
Enter
A typical value is 255.255.0.0
To change the subnet mask, type:
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com