133
Input, Event,
Freq
Input Range
Fault Cleared
This event occurs when the input signals frequency
offset becomes less than the maximum offset
frequency for the given Clock module.
134
Input, Event,
Msg
Input Port
Sync Quality
Level
Changed
This event occurs when the input ports received SSM
changes.
136
Equipment,
Event, Alarm
Critical Alarm
Cleared
This event signals that the CPU has turned off the
major alarm LED and relays and is not reporting a
critical alarm.
137
Message,
Event, Oper
User Set
Clock
AutoReturn
This event signals that the operator has turned the
clock autoreturn flag on or off.
138
Message,
Event, Oper
User Set E1
Input SSM Bit
This event signals that the operator has changed the
E1 SSM bit setting for reading the input ssm.
139
Input, Event,
SQL
Input Sync
Quality Level
is Better than
the Clock
Sync Quality
Level
This event signals that the read input ssm is better
than the clock holdover ssm.
140
Input, Event,
Msg
Lost Clock
Reference
Signal
This event signals that the Input module has lost the
reference signal from the specified Clock module. It
may signify an error on either module.
141
Input, Event,
Msg
Clock
Reference
Signal
Restored
This event signals that the Input module has regained
the reference signal from the specified Clock module.
142
Input, Event,
Msg
Input Signal
Fault Cleared
This event signals that the input port has been
restored from the signal error that created a failure.
This event is generated only when the ports
corresponding alarm mode flag is set to fail.
143
Input, Event,
Alarm
Input Module
Halt Cleared
This event signals that the Input module has started
normal operation after signalling that the halt condition
has been reached. Currently this event can never
happen but was added for TL1 purposes.
144
Input, Minor,
Msg
Input Port 3
Sigma Fault
This event signals that the input port phase error
change has crossed the 3 sigma threshold for that
input. The 3 sigma limit is calculated on the read
phase and is used to determine possible noise bursts.
Table B-5. Event Listing (Continued)
Event
No.
Type
Description
Comment