12778474-002-2 Revision F – March 2004
TSG-3800 User’s Guide 347
System Administrator’s Reference
Command Reference
Event Command
Use this command to display up to 500 prior event messages or to clear prior event
messages.
Frame Generator Command
Use this command to display and provision the Frame Generator modules.
Level 0
Not applicable
Level 1
EVENT [TYPE] [start number] [number]
EVENT [TYPE] [[startdate] [starttime]] [[stopdate]
[stoptime]
where:
Type is the type of message:
Message = informational messages
Input = messages related to the Input signals
Equipment = messages related to the hardware
All = above three types of messages
start number is the first message number
number is the number of messages to display in chronological order
startdate/stopdate is entered as mm/dd/yyyy
starttime/stoptime is entered as hh:mm
Level 2
Same as Level 1 operation
Level 3
EVENT [TYPE] [start number] [number of events]
EVENT [TYPE] [[startdate] [starttime]] [[stopdate]
[stoptime]
EVENT CLEAR
where:
Clear deletes every entry in the event list
Level 4
Same as Level 3 operation
Remarks
None
Related
DISABLE
COMM MODE
Restrictions
None
Level 0
Not applicable
Level 1
FG [A|B] [MODE]
FG [A|B] SET
FG DELAY
where:
Set displays the SSM value. If the SSM mode is manual, then hex values
are displayed; if it is auto, then the ASCII equivalent is displayed
Delay displays the amount of time before a change in SSM takes place
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com