TSG-3800 User’s Guide 331
System Administrator’s Reference
Provisioning Input Reference Signals
TSG->INPUT LOS
LMT is the current value of the 1-second alarm thresholds. MODE is the current
fault mode. INP1.1 through INP4.1 list the current 1-second error and clear count for
each channel.
Assigning Input Fault Modes
You can assign an individual fault mode for each type of signal fault. Fault modes
are: Fail, Alarm, Report, Ignore. Refer to section 3.5, Alarm Conditions for
explanations.
To assign a fault mode to an input fault, type:
INPUT «input» [LOS|CRC|AIS|BPV|OOF]
[FAIL|ALARM|REPORT|IGNORE]
then press
Enter
where «input» is described in
Table B-3
Example
Purpose: Change the INP4.1 AIS fault mode to Alarm.
Command:
INPUT INP4.1 AIS ALARM
Display:
TSG->INPUT INP4.1 AIS ALARM
«date» «time» «oper» set AIS Alarm mode to Alarm, was
Report for «input»
TSG->
Setting the Error Limit
The TSG-3800 counts the number of 1-second intervals that contain one or more
episodes. Each input fault has a separate timer. When this timer exceeds the error
limit, the TSG-3800 will respond according to the user specified fault mode.
The default error limit is 10. Changing this limit affects this limit only.
To change the error limit, type:
INPUT «input» [LOS|CRC|AIS|BPV|OOF] ERROR «threshold»
then
press
Enter
.
where «input» is described in
Table B-3
«threshold» is a number from 1 to 43,200 for OOF, BPU and CRC
and 1 to 100 for LOS and AIS
Module
Err Cnt
Clr Cnt
Err Lmt
Clr Lmt
Mode
Inp1.1
14
0
10
2
Fail
Inp2.1
0
57
10
2
Fail
Inp3.1
0
33
10
2
Fail
Inp4.1
0
57
10
2
Fail