Output Modules
Timing Insertion Module
286
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Making Signal Connections
The output signals are available at the 50-pin connectors located on the rear panel
of the shelf. Outputs one through 20 are used by this module. Refer to
Making
Output Signal Connections
, on page 56, for more information. Make DS1
input/output signal connections as shown in
Table 7-57
.
Operational Check
With power applied to the shelf, install the Timing Insertion module in the
appropriate slot and verify that the POWER indicator is lit. This indicates that the
module is receiving power and the module power supply is working.
Verify that the module is receiving the proper DS1 input signals by observing the
indicators. For normal operation the Power indicators should be lit; all others should
be off.
Table 7-57. List of Modules and Accessories
Pin
Description
1
EAST Tip In
2
EAST Tip Out (re-timed)
3
WEST Tip In
4
WEST Tip Out
5
Slip relay (normally open)
26
EAST Ring In
27
EAST Ring Out (re-timed)
28
WEST Ring In
29
WEST Ring Out
30
Slip relay (normally open)
Note:
The module indicators may take a few seconds after
installation to reach proper operating status.