CPU, Frame Generator, and Clock Modules
CPU Module
176
TSG-3800 User’s Guide
12778474-002-2 Revision F – March 2004
Figure 6-3
illustrates COMM A jumper settings configured for connection to a PC,
and COMM B jumper settings configured for connection to a modem.
Figure 6-3.
Jumper Settings
Installing the CPU Module
The CPU module must be installed in slot 5 of the TSG-3800 main shelf. See
Slot
Location and Keyed Modules
, on page 61.
Operational Check
Perform the following operational checks after installing the CPU module in the
main shelf. It is assumed that power has been connected to the shelf and is turned
on, and that there is a CPU module installed and functioning properly. A proper
external reference signal must be connected to the corresponding connector on the
rear panel of the main shelf. If used, the fault signal should also be connected to the
main shelf.
Table 6-4. Jumper Positions for Different Devices
COMM A
W14
W13
W7
W11
PC
1-2, 3-4
3-4
1-2
4-6
Mac
1-3, 2-4
7-8
5-6
1-2
Modem
1-3, 2-4
1-2
3-4
4-6
COMM B
W15
W16
W8
W9
PC
1-2, 3-4
3-4
1-2
4-6
Mac
1-3, 2-4
7-8
5-6
1-2
Modem
1-3, 2-4
1-2
3-4
4-6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com