SVAN 973 User Manual
54
7 CONFIGURING INSTRUMENT
– Instrument
The
Instrument
section is mainly related to the
configuration of the hardware components of the
instrument.
To open the
Instrument
section, press the
<Menu>
key,
select the
Instrument
position and press
<Enter>
.
<ENT>
The
Instrument
section contains following items:
User Interface
allowing you to choose the user interface option;
Battery
allowing you to display information about current power source;
Keyboard
allowing you to program some keyboard functions;
Power Off
allowing you to switch off the instrument power in case of inactivity;
USB
allowing you to configure the USB interface. This position is available only in the
Advanced
user interface mode;
Bluetooth
allowing you to switch on/off Bluetooth;
RS232
allowing you to configure the RS232 interface;
RTC
allowing you to set the Real Time Clock;
Unit Label
allowing you to display instrument properties.
7.1 C
HOOSING USER INTERFACE MODE
–
U
SER
I
NTERFACE
There are three modes of the user interface:
Start/Stop
,
Simple
or
Advanced
. These modes can be selected in
the
User Inter.
screen. The
Simple
mode enables basic
instrument settings, while the
Advanced
mode - full
scope of settings. Many screens thus have different
views in different interface modes.
<ENT>
The
Start/Stop
mode limits the user interface to only one
User
Interface
position in the main
Menu
and
measurement screens.
<Menu>
Note: When you switch the interface mode from Advanced to the other
there always appear the request “Do you restore the default value of
the advanced settings?” If the answer is “No”, then all settings that were
made in positions not active in the Simple mode will stay unchanged.
If answer is “Yes”, then these positions will be changed to default
settings.
7.2 C
HECKING POWER
–
B
ATTERY
The
Battery
position
enables checking the power source
condition. The instrument can be powered from four AAA
rechargeable or standard alkaline batteries or from the
USB-C interface.
The view presented on the display depends on the
current power source.
<ENT>
Summary of Contents for SV 973
Page 157: ...SVAN 973 User Manual Appendixes 157 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 158: ...SVAN 973 User Manual Appendixes 158 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 159: ...SVAN 973 User Manual Appendixes 159 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 172: ...SVAN 973 User Manual Appendixes 172 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 173: ...SVAN 973 User Manual Appendixes 173 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 174: ...SVAN 973 User Manual Appendixes 174 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 185: ...SVAN 973 User Manual Appendixes 185 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...