SVAN 973 User Manual
24
The
instrument’s memory is organised as a standard
memory with directories and sub-directories (FAT32 file
system). It is possible to create or delete directories.
The content of the memory can be checked with the help
of the
File Manager
position in the
File
section.
◄
Automatic saving logger and wave files
Logger and wave files are created and saved automatically. To enable automatic saving several
conditions should be fulfilled:
1. There should be enough free space in the memory.
2. The
Logger
(
path: <Menu> / Measurement / Logging / Logger Set.
) and/or
Recording
(
path:
<Menu> / Measurement / Logging / Wave Rec.
) should be enabled.
3. The new file should be defined with a unique name (
path: <Menu> / Measurement / Logging /
Logger Set. / Logger Name
and
path: <Menu> / Measurement / Logging / Wave Rec. / File Name
).
Files are saved in the directory, which was set as a working directory. The default working directory (after
using
Factory Settings
function) is called
SVANTEK
.
Note: During the
measurement run with data logging to the logger file, the “logger” icon is
displayed.
The file name (Logger or Wave) is generated automatically using a pattern
LLdd
,
where
LL
is the string of letters (so called
prefix
) and
dd
is a string of digits that
forms a number. Up to 8 characters can be used to name a file.
The default prefix for the logger files is
L
and for the wave files -
R
.
The instrument assigns an individual counter to each prefix of files the user has
created and saved in the working directory. The counter value is equal to the
maximum number in the set of files with the same prefix. For example, if there are
files with names:
L0
,
L15
and
L16
, the counter value is 16.
The number of the new automatically created file will have the value of the counter
increased by one. So, for the above example, new file name will be
L17
.
You can change the automatically generated file name in
the special screen, which is opened after pressing the
◄ / ► key.
After changing the number in file name without changing
the prefix and pressing
<Enter>
, the counter will be
automatically adjusted.
►
The instrument accepts only that name which number is
higher than the counter of the prefix.
<ENT>
Saving setup files
Setup files can be created by means of the
Setup Manager
or from the measurement screen with
the
<ESC>
key pressed with
<Shift>
, when a
measurement is not running.
All Setup files are stored in the default directory
SETUP
.
<Sh/ESC>
Summary of Contents for SV 973
Page 157: ...SVAN 973 User Manual Appendixes 157 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 158: ...SVAN 973 User Manual Appendixes 158 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 159: ...SVAN 973 User Manual Appendixes 159 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 172: ...SVAN 973 User Manual Appendixes 172 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 173: ...SVAN 973 User Manual Appendixes 173 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 174: ...SVAN 973 User Manual Appendixes 174 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 185: ...SVAN 973 User Manual Appendixes 185 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...