![Svantek SV 973 User Manual Download Page 196](http://html1.mh-extra.com/html/svantek/sv-973/sv-973_user-manual_1409271196.webp)
SVAN 973 User Manual
– Appendixes
196
The instrument contains a wireless transmission module, BGM121 from Silicon Laboratories technologies.
Copies of the modules regional approvals certificates may be obtained from Svantek or Silicon Laboratories.
•
Declaration ID: D033250, Controller Subsystem Qualified Design ID: 88831
FCC and ISEDC
This product contains an FCC and Industry Canada certified Bluetooth® Low energy wireless transmission
module:
•
FCC IDENTIFIER:
QOQBGM12LMA
•
Industry Canada IC:
5123A-BGM12LMA
•
Producer: Silicon Laboratories Inc.
•
Model: BGM121A Bluetooth smart module
•
Modular Type: Single Modular
FCC Statements:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End
users must follow the specific operating instructions for satisfying RF exposure compliance.
This transmitter meets both portable and mobile limits as demonstrated in the RF Exposure Analysis and SAR
test report. This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter except in accordance with FCC multi-transmitter product procedures.
ISEDC Statements:
This radio transmitter has been approved by Industry Canada to operate with its embedded antenna. Other
antenna types are strictly prohibited for use with this device. This device complies with Industry Canada’s
license-exempt RSS standards. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation
of the device.
Exception from routine SAR evaluation limits are given in RSS-102 Issue5. BGM121N meets the given
requirements when the minimum separation distance to human body is less than equal to 15 mm. RF exposure
or SAR evaluation is not required when the separation distance is 15 mm or more.
BGM121A module has been tested for worst case RF exposure. As demonstrated in the SAR test report,
BGM121A and BGM123A can be mounted in touch with human body without further SAR evaluation.
Weight with the battery
225 g (including microphone and preamplifier).
Dimensions
20x52x232 mm .
Environmental parameters
•
Working temperature range
-10
C
+50
C
•
Storing temperature range
-20
C
+50
C (-30
C
+60
C without batteries)
•
Humidity
90% RH in 40
C (uncondensed vapour)
Summary of Contents for SV 973
Page 157: ...SVAN 973 User Manual Appendixes 157 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 158: ...SVAN 973 User Manual Appendixes 158 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 159: ...SVAN 973 User Manual Appendixes 159 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 172: ...SVAN 973 User Manual Appendixes 172 250 Hz 315 Hz 400 Hz 500 Hz 630 Hz 800 Hz...
Page 173: ...SVAN 973 User Manual Appendixes 173 1000 Hz 1250 Hz 1600 Hz 2000 Hz 2240 Hz 2500 Hz...
Page 174: ...SVAN 973 User Manual Appendixes 174 2800 Hz 3150 Hz 3550 Hz 4000 Hz 4500 Hz 5000 Hz...
Page 185: ...SVAN 973 User Manual Appendixes 185 500 Hz 1 1 octave filter 250 Hz 1 1 octave filter...