![Suzuki GF60A Service Manual Download Page 70](http://html.mh-extra.com/html/suzuki/gf60a/gf60a_service-manual_1408873070.webp)
1A-18 Engine Control:
4
1) Check the MAP sensor output voltage change.
Refer to “MAP Sensor Output Voltage Inspection” in
Section 1C (Page 1C-12).
Is it in good condition?
Substitute a known-
good ECM and recheck.
• Faulty MAP sensor.
• “R” wire shorted to
“W” wire, “B/W” wire
open, poor “B/W”
wire connection, poor
“W” wire connection,
“W” wire open or poor
MAP sensor
connection.
• If the wiring and
connection is OK,
intermittent trouble or
a faulty ECM may be
the cause.
Step
Action
Yes
No