Chapter 3
Troubleshooting and Fault Isolation
67
Robotics Controller Fuse Isolation Entry MAP
Replace the robotics
controller (see “Robotics
Controller PWA” on
page 145).
On the robotics controller, connect
an ohm meter to a ground test point
and to a test point for the voltage of
the blown fuse (see
FIGURE 4-24
on
page 147). Resistance should be
less than two ohms. Short present?
Disconnect J8 (see
FIGURE 4-24
on page 147).
Short still present?
See “Actuator Driver Fuse
Isolation Entry Map” on
page 68.
Replace blown fuse.
Disconnect J7 (see
FIGURE 4-24
on page 147).
Short still present?
Replace the control panel
(see “Control Panel
Assembly” on page 141).
Replace blown fuse.
Disconnect J9 (see
FIGURE 4-24
on page 147).
Short still present?
See “Tape Drive Interface
PWA Isolation Map” on
page 83.
See “Fault Isolation Entry
MAP” on page 48.
No
No
No
No
Yes
Yes
Yes
Yes
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...