Appendix B
Sense Data Values
197
5
8A
02
UNCALIBRATED POSITION
System requires calibration.
Both
B
8C
01
LOAD PORT TIMEOUT
The door was unlocked but did not leave its
current position before time-out (30
seconds). This may be due to the door being
stuck, or in the case of a close operation, the
operator not moving the door.
Both
4
8C
06
LOAD PORT DOOR OPEN
The door is stuck in an intermediate position
(not opened and not closed.) Operation
intervention is required.
Both
B
8D
01
DLT™ DRIVE HANDLE MOTOR TPU
TIMEOUT
Replace robotics controller board.
Both
B
8D
02
DLT DRIVE HANDLE MOTOR MOVE
TIMEOUT
Retry command. If failure repeats, power
cycle unit. If failure repeats, run DLT Drive
Handle self-test.
Both
4
8D
03
DLT DRIVE HANDLE MOTOR CPU RAM
ERROR
Replace robotic controller board.
Both
4
8D
04
DLT DRIVE HANDLE MOTOR CPU
REGISTER ERROR
Replace robotic controller board.
Both
4
8D
05
DLT DRIVE HANDLE MOTOR
HARDWARE ERROR
Stepper was unable to reach destination
(open or close). Retry command. If failure
repeats, run DLT Drive Handle self-test.
Both
TABLE B-1
Sense Data Values (Hexadecimal) (Continued)
Sense
Key
ASC
ASCQ
Message Name/Description
Interface
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...