Chapter 4
FRU Removal and Replacement
99
X-Axis Interconnect PWA
Required Tools
Phillips screwdriver, flashlight
▼
To Remove the X-Axis Interconnect PWA
1. Remove power from the library.
Caution –
DO NOT disconnect the power cord from facility power or the library.
The power cord is the only means of grounding the chassis and helping to prevent
electrostatic discharge (ESD) damage.
2. Remove the top, left, and right side cosmetic panels as shown in “Top, Right, and
Left Panels” on page 92.
3. Connect your ESD wrist grounding strap to the closest grounding point on the
library frame.
4. Move the horizontal axis to the front of the library positioning the gripper
directly under the tape drives.
6211630-01
Tape Drive Interface PWA
130
0815033
Tape Drive Stepper Motor Assembly
132
6204202-01
Tape Drive Tray Assembly
134
6240320-01
Tape Drive Distribution PWA
136
6240330-01
Tape Drive MUX PWA
138
6210440-01
Control Panel Assembly
141
6210515-03
X-Axis Confirmation Sensor
143
6210470-01
Robotics Controller PWA
145
6210450-01
Actuator Driver PWA
148
0355038
Motor Power Supply Assembly
154
0355041
PC Logic Power Supply Assembly
151
TABLE 4-1
FRU List (Continued)
Part Number
FRU Name
Page
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...