70
Sun Enterprise Tape Library 7/3500 Field Service Manual • July 1997
Power Supply Evaluation Entry MAP (Cont.)
Replace motor power
supply PS3 (see “Motor
Power Supply
Assembly” on
page 154).
Replace actuator driver
PWA (see “Actuator
Driver PWA” on
page 148).
On the actuator driver PWA:
1. m48V test point
on TP2. B46V
and +49V?
2. m24V test point
on TP1. B22V
and +25V?
On the actuator driver PWA,
m48V on input side of
F1. B47V and +49V?
On the actuator driver PWA,
m24V on input side
of F2 (see
FIGURE 3-2
on
page 85). B23V
and +25V?
Continued from page
page 69. Actuator driver
power checkout.
Replace motor power
supply PS2 (see
“Motor Power Supply
Assembly” on
page 154).
Is red fault LED on
robotics controller on?
See “Motor Power
Interlock Clearing
MAP” on page 58.
See “Fault Isolation
Entry MAP” on
page 48.
No
No
No
No
Yes
Yes
Yes
Yes
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...