Chapter 3
Troubleshooting and Fault Isolation
77
Tape Drive Stepper Motor Self-Test Failure MAP
Replace robotics controller
PWA (see “Robotics Controller
PWA” on page 145).Retest
OK?
Unload specific tape drive
(see “To Unload a Drive” on
page 176). Does tape drive
handle move freely?
Check specific tape drive
interposer and drive status.
Replace specific tape drive (see
“Tape Drive” on page 127).
Retest OK?
Replace actuator driver PWA
(see “Actuator Driver PWA” on
page 148). Retest OK?
Replace specific tape driver
interface PWA (see “Tape
Drive Interface PWA” on
page 130). Retest OK?
Replace specific tape drive
stepper assembly (see “Tape
Drive Stepper Motor
Assembly” on page 132).
Call next level of
support.
See “Diagnostic
Test Entry MAP” on
page 53.
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...