58
Sun Enterprise Tape Library 7/3500 Field Service Manual • July 1997
Motor Power Interlock Clearing MAP
Replace robotics controller
(see “Robotics Controller
PWA” on page 145). Retest
OK?
1.M5V on Tp2 of robotics
controller, 5.05V and
+5.15V?
2.M12V on output side of F3 of
robotics controller, b11.5V
and +12.5V?
1. Check stop switch.
2. Check front door.
3. Check +5V,+12V.
4. Check microprocessor fault LED.
5. Check PC power good signal.
Replace PC power supply and adjust (see
“PC Logic Power Supply Assembly” on
page 151).
Stop LED is illuminated on control
panel?
Depress stop switch.
Verify AC power is on.
Door open LED is illuminated on robotics
controller?
See “Power Entry MAP” on
page 61.
Microprocessor fault LED is illuminated
on robotics controller?
PC Power Good signal on J15-pin1 of
robotics controller is high? See
FIGURE 3-1
on page 84.
See “Fault Isolation Entry
MAP” on page 48.
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Close front door.
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...