Sun Enterprise Tape Library 7/3500 Field Service Manual • July 1997
Online Test Entry MAP
Host connected to the SCSI port?
Connect host to SCSI port.
Request sense data from the
library. Is communication between
host and library OK?
See “Host Interface Failure
MAP” on page 54.
Perform move medium test between
bins and drives. Operate load port
from control panel. Does the library
operate properly?
See “Library Operation
Failure MAP” on page 55.
Library is OK. Clean up, replace
cosmetic panels (see “Replacing
the Cosmetic Panels” on page 159),
and perform final inspection.
See “Fault Isolation Entry
MAP” on page 48.
You are done.
No
No
No
Yes
Yes
Yes