50
Sun Enterprise Tape Library 7/3500 Field Service Manual • July 1997
Mechanical Inspection Entry MAP
1. Inspect drive belts
2. Check for movement
3. Check cartridges
Inspect and manually move the
x-axis belt (see
FIGURE 2-11
on
page 40).
Belt and motor appear OK?
1.Tighten or adjust as required
(see page 37).
2. Replace if required (see
page 116).
Inspect and manually move the
y-axis belt (see
FIGURE 2-9
on
page 37).
Belt and motor appear OK?
1. Tighten or adjust as required (see
page 35).
2. Replace if required (see page 118).
Inspect and manually move the
extension axis belt (see
FIGURE 2-11
on page 40).
Belt and motor appear OK?
Verify that the cartridges are
fully seated in the storage array.
Seat cartridges.
See “Fault Isolation Entry
MAP” on page 48.
No
No
No
No
Yes
Yes
Yes
Yes
1. Tighten or adjust as required (see
page 41).
2. Replace if required (see “X-Axis
Drive Belt” on page 116).
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...