Actuator Driver Fuse Isolation Entry Map
Replace the extension axis
(see “Extension Axis
Assembly” on page 126).
Replace blown fuse.
Replace the x-axis
interconnect PWA (see “X-
Axis Interconnect PWA” on
page 99). Replace blown
fuse.
On the actuator driver PWA,
connect an ohm meter to a
ground test point and to the
test point for voltage of the
blown fuse (see
FIGURE 3-2
on
page 85). Resistance should
be less than 10 ohms.
Short present?
Replace blown fuse.
See “Fault Isolation Entry
MAP” on page 48.
Replace the actuator driver PWA
(see “Extension Axis Assembly”
on page 126). Replace blown
fuse if required.
Disconnect J5 (see
FIGURE 3-2
on page 85).
Short still present?
Disconnect J4 (see
FIGURE 3-2
on page 85).
Short still present?
No
Yes
No
No
Yes
Yes
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...