100
Sun Enterprise Tape Library 7/3500 Field Service Manual • July 1997
Note –
The PWA is accessed through the service port directly under the tape drives.
5. From the right side, remove the Phillips screws securing the strain relief to the
PWA.
6. Disconnect the cables.
7. From the left side, remove the ESD guard mounting hardware.
8. From the right side, remove the guard and liner.
Caution –
Pay attention to the orientation of connector Px when you remove it.
Reinstalling connector A4_J4 incorrectly causes the library robotics to malfunction
and may cause damage to the library.
9. Disconnect the horizontal home sensor, connector A4_J4.
10. Disconnect the y-axis motor connector A4_K3.
11. Remove the remaining two Phillips screws that secure the PWA to the horizontal
frame.
12. Carefully lift the PWA out of the library.
▼
To Replace the X-Axis Interconnect PWA
●
Follow the removal instructions in reverse order.
▼
To Troubleshoot
●
If the library malfunctions, check the orientation of the horizontal home sensor
connector A4_J4 and reseat it if necessary.
Summary of Contents for Enterprise Tape Library 7/3500
Page 10: ...x Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 26: ...xxvi Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 28: ...xxviii Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 76: ...46 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 118: ...88 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 192: ...162 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 231: ...Glossary 3 ZIF connector Zero insertion force connector ...
Page 232: ...4 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...
Page 242: ...10 Sun Enterprise Tape Library 7 3500 Field Service Manual July 1997 ...