ECO ARC 600
9-1
Revision 1/10/08
9
Appendix
9.1
Recommended spray parameters for Sulzer Metco wire arc spray
systems
Please consider:
- The parameters in this chart are just for orientation. Depending of the coat’s character parame-
ters can be modified.
- The spray amperage has to be adjusted depending on the desired output. The higher the
amperage the higher the output.
- You have to to care that a faultless melting behavior of the wire is guaranteed, which means to
adjust the operating voltage as needed.
- Small and thin-walled workpieces should be sprayed with reduced amperage to avoid high
thermal stress inside the coating.
Wi
re
t
y
p
e
Wire
Parameters for bond coat
Parameters for top coat
Voltage [V]
Air [bar]
Voltage [V]
Air [bar]
SOFT WIRES
OSU 001
--
--
18 - 20
3,0 - 5,0
OSU 002
--
--
18 - 20
3,0 - 5,0
OSU 004
27 - 42
1,5 - 2,0
26 - 29
3,0 - 5,0
OSU 006
27 - 42
1,5 - 2,0
26 - 29
3,0 - 5,0
Summary of Contents for ECO ARC 600
Page 6: ......
Page 47: ...ECO ARC 600 5 1 Revision 1 10 08...
Page 74: ...ECO ARC 600 7 6 Revision 1 10 08...
Page 75: ...ECO ARC 600 8 1 Revision 1 10 08...
Page 88: ...ECO ARC 600 8 14 Revision 1 10 08 T2 K1 A10 F4 D10 F2 1 F2 2 F3 K3 F21 F22 F23...