![Sulzer Metco ECO ARC 600 Manual Download Page 63](http://html1.mh-extra.com/html/sulzer-metco/eco-arc-600/eco-arc-600_manual_1390515063.webp)
ECO ARC 600
6-7
Revision 1/10/08
Indication
Cause
Remedy
Power supply
Control transformer
Only specialist staff is allo-
wed to work at electrical
appliances.
Before opening the power
supply pull out the mains
plug!
Check control transformer.
Power supply
Condenser for pre cleaned
compressed air
Filter pad is blocked
Check filter pad
(s. maintenance)
or
Change blocked filter pad
Operate system only with
assembled filter pad.
If not solenoid valve will be
damaged
No oil in the oiler
Air motor deadlocked
Check the oiler
Refill air motor oil
Oil the air motor (air input)
(s. maintenance)
Put air motor for repair
Indication
Cause
Remedy
or
Spray wire
Gets scorched in contact
nozzle.
Inaccurate melting down.
Forms short-circuit.
Use different spray wire.
Get advised by SMOSU-
customer service.
OFF OFF OFF
ON OFF BLINKING
System OFF
Error Air
ON OFF ON
System OFF
Error Overload
System OFF
Error Underload
Summary of Contents for ECO ARC 600
Page 6: ......
Page 47: ...ECO ARC 600 5 1 Revision 1 10 08...
Page 74: ...ECO ARC 600 7 6 Revision 1 10 08...
Page 75: ...ECO ARC 600 8 1 Revision 1 10 08...
Page 88: ...ECO ARC 600 8 14 Revision 1 10 08 T2 K1 A10 F4 D10 F2 1 F2 2 F3 K3 F21 F22 F23...
Page 94: ...ECO ARC 600 9 2 Revision 1 10 08 9 2 Circuit diagram...