System does not start, system cuts out
Indication
Cause
Remedy
Hose package
Short-circuit between both
current-air-cables:
Insulation damaged
Measure resistance (short-
circuit) between current-air-
cables
Power supply
- Turn main switch OFF
- demount hose package
Spray device
- Clip off spray wire at the
contact nozzles
- Wire tips must not touch
each other
Measure resistance (short-
circuit) between current-air-
cables. Wire tips must not
touch each other
Short-circuit between both
current-air-cable:
- Put hose package for repair
Spray device
Air motor does not work
Unscrew compressed air
hose for air motor of spray
device
Compressed air is blowing:
- Check grid in double nipple
at the air input of air motor
Clean or replace