ECO ARC 600
3-2
Revision 1/10/08
For other combinations of the values for ambiemt temperature and
positioning altitude, the values of the continuous on-state current (from
the same line) must be multiplied.
Example:
Ambient temp. = 63° C (corresponds to 80% of the cont. on-state cur-
rent) and
Pos. alt. = 1700 m (corresponds to 90% of the cont. on-state current)
Continuous on-state current = 80% x 90% = 72%
Hose package
Weight
Length
Standard length
15,6 kg
8 m
Spray capacity ECO ARC 600
max. melting capacity at 100% duty cycle
•
Zn
=
60,0 kg / h
•
ZnAl15
=
53,0 kg / h
•
Al
=
18,0 kg / h
•
AlMg5
=
16,0 kg / h
Permissible current loading for silicon rectifier
Continuous on-state
current [%]
Ambient temperature
[° C]
Positioning altitude
[m above sea level]
100
45
1000
90
54
1700
80
63
2900
70
72
4200
60
81
6000
50
90
40
100
The rectifier is fitted with thermostatic switches to guard against overhea-
ting.
Please note!
Short-circuits can very quickly destroy the silicon rectifier.
Destruction due to short-circuit overloads can not be claimed as a cause of
defects.