ECO ARC 600
6-2
Revision 1/10/08
6.1
System does not start
Indication
Cause
Remedy
Three phase
current
System is not switch ON
Switch ON system with main
switch
Three phase power supply of
system
Check fuse in three phase
current supply system
Wrong mains power supply
Check mains power supply
Check connections (see type
plate)
Compressed air
supply
Compressed air not connec-
ted
Check compressed air con-
nection
Air compressor
Malfunction or switched OFF
Check air compressor
Valve closed in compressed
air mains
Check ring mains and produ-
cer of compressed air
Pressure is too low
Ring mains or compressor
have to supply compressed
air at min. of 2,5 bar
Cross-section of pipe is too
small
Volumetric flow (Nm³ / h) too
low
Required cross-section of
compressed air supply:
min. 20 mm (3/4’’) max. 10 m
better 25 mm (1’’)
Volumetric flow: 150 Nm³ / h
at 4 bar
Filter pad is blockedpad
Check filter pad in condeser,
clean or change
OFF OFF OFF
ON OFF BLINKING
System OFF
Error Air