Aluminum and aluminum alloys used as corrosion protection coa-
tings should always be sprayed at the maximum voltage (step 5)
and with the highest atomizer air pressure. These coatings are
finer grained and more dense and have a higher anticorrosion
value.
5.4.5 Setting-up the oiler
•
The oiler is set to a frequency of 1 drop each 6 seconds (at a run-
ning machine). When the oiler set-up does not match this fre-
quency, it can be regulated with a screw driver. The oil overrun is
automatically traced back into the reservoir.