ECO ARC 600
6-6
Revision 1/10/08
Indication
Cause
Remedy
Power supply
Build-up of heat
Power supply covered.
Switching OFF by tempera-
ture sensitive switch.
Convection cooling not insu-
red.
Leave cooling air slot (in /
out) blank
Let cool down until green
signal lamp lights.
Cooling time:
Rectifier: ca. 5 min.
Transformer max. 2 h
AC-Motor: ax. 30 min.
Build-up of heat
Power supply dusty from the
inside
Switching OFF by tempera-
ture sensitive switch.
Clean power supply from the
inside
(s. maintenance)
Let cool down until green
signal lamp lights.
Cooling time:
Rectifier: ca. 5 min.
Transformer max. 2 h
Temperature of environment
too high
Ventilate
Push-Motor too hot.
Switching OFF by tempera-
ture sensitive switch.
Push-gear:
Pressure rolls must run
easly.
Clean pressure rolls.
Grease bore (drilling) of pres-
sure rolls.
(s. maintenance).
Check position of wire feed
step switch and change if
necessary.
Let cool down until green
signal lamp lights.
ON OFF BLINKING
System OFF
Error Temp.