ECO ARC 600
6-11
Revision 1/10/08
6.5
Electric arc shuts off, spray wires not feeding, push gear running
Indication
Cause
Remedy
Power supply
Solenoid valve defective.
(Comp. air - air motor)
Spray device:
Push OFF-button.
Unscrew compressed air
hose of power supply.
Spray device:
Push ON-button.
If no air is blowing at the
compressed air hose con-
nection - replace solenoid
valve.
Spray device
Air motor defective
Compressed air is leaking:
Demount air motor and put
for repair.
(s. maintenance)
Hose package
Air motor hose defective
Replace air motor hose
or put for repair.
ON OFF ON
System OFF
Error Overload