5.5
Further instructions
•
Before starting work each day check that all safety measures and
precautions for thermal spraying have been taken.
•
Check personal protective equipment each day before starting
work.
•
Check the production parameters.
•
For coating larger, joined surfaces it is an advantage to exchange
the standard round stream system for a flat spray system.
•
Please seek our advice.
•
Perform functional monitoring of the machine each day.
•
The hose and cable set should not be kinked. Lay out in large
loops only.
•
Ensure spray wire is clean and dust-free.
•
Check the quality of the compressed air.
•
Empty the condenser daily.
•
Check the oil level and delivery of the oiler weekly.
Top up only with suitable oil.
•
If the compressed air contains large amounts of oil and water, this
condensate will also reach the oiler and adversely affect the air
motor oil. The oil must then be changed.