Warning: Broken UV lamp hazard
UV lamps contain mercury. Deal with broken lamps with caution.
l
Ventilate the room thoroughly.
l
Use protective gloves when collecting mercury and lamp components.
l
Remove spilled mercury with a method that prevents the generation of
mercury vapor, such as a syringe, packing tape or paper.
l
Place the broken lamp, mercury and contaminated materials in an air-tight,
non-metallic container.
17. Insert the UV reflector unit into the housing, next to the print block.
Figure 4-155 Print block and UV lamp assembly, showing correct
placement of black strip
18. Replace the UV lamp cover by inserting it into the slot on the bottom of the
housing, and tighten the securing screw on top.