Stratasys J750/J735/J720 User Guide
4 Operating and Maintaining the Printer
DOC-08040 Rev. R
4-81
Figure 4-118 Final UV Calibration Wizard screen
Calibrating the Load Cells
Load cells are sensors that measure the weight of the material cartridges and the
waste container in the printer. It is important that you periodically check that the
weight measurements are accurate to prevent unnecessary waste of printing
materials or printer malfunctions.
To calibrate load cells:
1. Start the Load Cell Calibration wizard from the
Options
menu.
2. In the following screen, select one or more load cells that you want to
calibrate.
Figure 4-119 Load cell selection
3. Remove each selected cartridge from the materials cart, and click
Next
.
4. In the next wizard screen, observe the numbers and wait until the weight level
is relatively stable—two units above or below the average level shown.