Stratasys J750/J735/J720 User Guide
4 Operating and Maintaining the Printer
DOC-08040 Rev. R
4-92
10. Holding a new pump cassette with one hand, gently pull on each of the tubes.
Pulling on the tubes before installing the cassette ensures that the pump
mechanism turns freely.
Figure 4-137 Preparing the pump cassette for installation
11. Attach the new pump cassette to the printer.
Fit the cassette into the slots in the housing, and turn clockwise to working
position.
12. Connect the tubes to the new pump cassette.
13. If necessary, replace the pump cassette on the other waste pump.
14. Connect the ground wire to the printer panel.
15. Attach the panel to the printer.
16. Open the
Maintenance Counters
screen, scroll down to the
General Pumps
section, and click
Reset
for the relevant counter(s) (see Figure 4-130 on